2/2-way coaxial valve; Directly operated; G1/2"; 0...100bar; 24VDC; DN10; NC; Body: Brass; Medium: Diesel oil +80°C; Terminal box; Incl. mounting bracket; Special seals; Epoxy resin coating; Incl. 3 inductive limit switches (B.); 3x Position OPEN; incl. cable socket 10m; ATEX Ex II 3G Ex ec IIC T3 Ta -20…+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20…+80°C Dc; Ex II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc; Incl. inspection certificate 3.1; Incl. material certificate; Special version
2/2-way coaxial valve; directly operated; G1/2"; 0...40bar; 220VDC; DN15; NC; body: stainless steel; medium: hydrogen; back pressure tight; terminal box; manual emergency override; incl. 2 inductive NAMUR limit switches OPEN/CLOSED (B.); special seals; Vacuum leak test with certificate; inspection certificate 3.1; material certificate; ATEX CE Ex II 3G Ex ec IIC T3 Ta -20…+80°C Gc / II 3D Ex tc IIIC T195°C Ta -20…+80°C Dc and Ex II 3G Ex h IIC T3 Gc / II 3D Ex h IIIC T195°C Dc; special version