Female thread Length U max. I max. Maximum pressure Switching range Type Sequence
G 1" 130 mm 250 V 3 A 300 bar 15...45 l/min RVM/U-1/45-VA 32860017
G 1" 130 mm 250 V 3 A 300 bar 20...60 l/min RVM/U-1/60-VA 32860018
G 1" 130 mm 250 V 3 A 300 bar 30...90 l/min RVM/U-1/90-VA 32860019
Flow monitors Series RVM/U-L

Flow monitors Series RVM/U-L

Body, Float Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Air scale; Switching range at 1 bar absolute; 20°C; NO contact

Strömungswächter Serie RVM/U-L Strömungswächter Serie RVM/U-L
Grundversion
Female thread Length U max. I max. Maximum pressure Switching range Type Sequence
G 1/4" 70 mm AC140/DC200 V AC0,7/DC1 A 350 bar 3...22 Nl/min RVM/U-4/06-VA-L 32870000
G 1/4" 70 mm AC140/DC200 V AC0,7/DC1 A 350 bar 16...56 Nl/min RVM/U-4/2-VA-L 32870001
G 1/4" 70 mm AC140/DC200 V AC0,7/DC1 A 350 bar 20...80 Nl/min RVM/U-4/3-VA-L 32870002
DKM-2/2-MS
Flow monitors Series DKM; Viscosity compensated 32...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; NO contact; Application: Monitoring of lubrication; Connection 1/2"; Switching range 0,5...1,6L/min; Maximum pressure 300bar; U max. 230V; I max. 3A; Length 90mm
Female thread Length U max. I max. Maximum pressure Switching range Type
G 1/2" 90 mm 230 V 3 A 300 bar 0,5...1,6 l/min DKM-2/2-MS
RVM/U-L40002-VA
Flow monitors Series RVM/U-L; Body, Float Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Air scale; Switching range at 1 bar absolute; 20°C; NO contact; Connection 1/4"; Switching range 0,6...2,2Nl/min; Maximum pressure 350bar; U max. AC140/DC200V; I max. AC0,7/DC1A; Length 65mm
Female thread Length U max. I max. Maximum pressure Switching range Type
G 1/4" 70 mm AC140/DC200 V AC0,7/DC1 A 350 bar 0,6...2,2 Nl/min RVM/U-L40002-VA
DKM-2/3-MS
Flow monitors Series DKM; Viscosity compensated 32...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; NO contact; Application: Monitoring of lubrication; Connection 1/2"; Switching range 0,8...3L/min; Maximum pressure 300bar; U max. 230V; I max. 3A; Length 90mm
Female thread Length U max. I max. Maximum pressure Switching range Type
G 1/2" 90 mm 230 V 3 A 300 bar 0,8...3 l/min DKM-2/3-MS
RVM/U-L40006-VA
Flow monitors Series RVM/U-L; Body, Float Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Air scale; Switching range at 1 bar absolute; 20°C; NO contact; Connection 1/4"; Switching range 1,7...6Nl/min; Maximum pressure 350bar; U max. AC140/DC200V; I max. AC0,7/DC1A; Length 65mm
Female thread Length U max. I max. Maximum pressure Switching range Type
G 1/4" 70 mm AC140/DC200 V AC0,7/DC1 A 350 bar 1,7...6 Nl/min RVM/U-L40006-VA
Flow monitors Series DKM

Flow monitors Series DKM

Viscosity compensated 32...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; NO contact; Application: Monitoring of lubrication

Strömungswächter Serie DKM
Grundversion
Female thread Length U max. I max. Maximum pressure Switching range Type Sequence
G 1/2" 90 mm 230 V 3 A 300 bar 2...7 l/min DKM-2/7-MS 32870004
G 1/2" 152 mm 250 V 3 A 250 bar 2...8 l/min DKM-1/8-12-MS 32870005
RVM/U-L40008-VA
Flow monitors Series RVM/U-L; Body, Float Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Air scale; Switching range at 1 bar absolute; 20°C; NO contact; Connection 1/4"; Switching range 2,5...8Nl/min; Maximum pressure 350bar; U max. AC140/DC200V; I max. AC0,7/DC1A; Length 65mm
Female thread Length U max. I max. Maximum pressure Switching range Type
G 1/4" 70 mm AC140/DC200 V AC0,7/DC1 A 350 bar 2,5...8 Nl/min RVM/U-L40008-VA
DKM-1/10-34-MS
Flow monitors Series DKM; Viscosity compensated 32...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; NO contact; Application: Monitoring of lubrication; Connection 3/4"; Switching range 3...10L/min; Maximum pressure 250bar; U max. 250V; I max. 3A; Length 152mm
Female thread Length U max. I max. Maximum pressure Switching range Type
G 3/4" 152 mm 250 V 3 A 250 bar 3...10 l/min DKM-1/10-34-MS
RVM/U-L40012-VA
Flow monitors Series RVM/U-L; Body, Float Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Air scale; Switching range at 1 bar absolute; 20°C; NO contact; Connection 1/4"; Switching range 3...12Nl/min; Maximum pressure 350bar; U max. AC140/DC200V; I max. AC0,7/DC1A; Length 65mm
Female thread Length U max. I max. Maximum pressure Switching range Type
G 1/4" 70 mm AC140/DC200 V AC0,7/DC1 A 350 bar 3...12 Nl/min RVM/U-L40012-VA
DKM-1/30-34-MS
Flow monitors Series DKM; Viscosity compensated 32...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; NO contact; Application: Monitoring of lubrication; Connection 1"; Switching range 10...30L/min; Maximum pressure 250bar; U max. 250V; I max. 3A; Length 152mm
Female thread Length U max. I max. Maximum pressure Switching range Type
G 3/4" 152 mm 250 V 3 A 250 bar 10...30 l/min DKM-1/30-34-MS
Flow monitors Series RVM/U-L

Flow monitors Series RVM/U-L

Body, Float Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Air scale; Switching range at 1 bar absolute; 20°C; NO contact

Strömungswächter Serie RVM/U-L Strömungswächter Serie RVM/U-L
Grundversion
Female thread Length U max. I max. Maximum pressure Switching range Type Sequence
G 1/4" 70 mm AC140/DC200 V AC0,7/DC1 A 350 bar 7...24 Nl/min RVM/U-L40024-VA 32870007
G 1/4" 70 mm AC140/DC200 V AC0,7/DC1 A 350 bar 12...34 Nl/min RVM/U-L40034-VA 32870008
DKM-1/2-MS
Flow monitors Series DKM; Viscosity compensated 32...600mm²/s; Body Nickel plated brass; For any mounting position; Medium temperature Max. 120°C; Oil scale; NO contact; Application: Monitoring of lubrication; Connection 1"; Switching range 0,5...1,5L/min; Maximum pressure 250bar; U max. 250V; I max. 3A; Length 130mm
Female thread Length U max. I max. Maximum pressure Switching range Type
G 1" 130 mm 250 V 3 A 250 bar 0,5...1,5 l/min DKM-1/2-MS
RVM/U-2/20-VA-L
Flow monitors Series RVM/U-L; Body, Float Stainless steel 1.4571; For any mounting position; Medium temperature Max. 120°C; Air scale; Switching range at 1 bar absolute; 20°C; NO contact; Connection 1/2"; Switching range 140...525Nl/min; Maximum pressure 350bar; U max. 230V; I max. 3A; Length 90mm
Female thread Length U max. I max. Maximum pressure Switching range Type
G 1/2" 90 mm 230 V 3 A 350 bar 140...525 Nl/min RVM/U-2/20-VA-L